THE BUYER'S GUIDE / SELECTION
This guide helps procurement engineers and system integrators evaluate whether the 100~6200MHz 50w Function with VSWR、Detection、TEMP module from YiYuan ComTech Co., Ltd. matches their application requirements. It covers the key electrical specifications, the built-in monitoring interface, and the practical conditions under which this broadband solid-state power amplifier is an appropriate fit—so buyers can make an informed sourcing decision.
Frequency band compatibility: confirm all system operating frequencies fall within 100 MHz to 6000 MHz; applications above 6000 MHz are outside the module's rated range.
Output power and supply requirements: verify that 50 W CW output at 24–32 V DC with a separate 5 V bias rail (Hybrid D-Sub 10-Pin connector) and at least 3.5 A current draw at full output is supported by the host platform.
Monitoring interface integration: assess whether the host system can use the VSWR alarm (Pin 3), TEMP analog output at 10 mV/°C (Pin 2), forward power detection at 50 mV/1 dB (Pin 8), and current sense at 100 mV/A (Pin 7), and confirm TTL 3.3 V logic compatibility for the PA_EN enable line (Pin 4).
Application profile alignment: match to broadband signal applications such as jamming, multi-band communication relay, or OEM wideband transmit chains requiring frequency agility and an integrated monitoring suite; not suited for single-band low-power systems or frequencies above 6 GHz.
This article is for RF system engineers, procurement managers, and OEM integrators evaluating broadband solid-state power amplifier (SSPA) modules. The focus is on determining whether the 100~6200MHz 50w Function with VSWR、Detection、TEMP module from YiYuan ComTech Co., Ltd. matches the technical demands of a specific system before committing to procurement.
No pricing, lead-time, or export certifications are addressed here; all specifications cited are drawn directly from the published product data.
The 100~6200MHz 50w Function with VSWR、Detection、TEMP is a GaN-based broadband RF solid-state power amplifier module. Its defining characteristics are:
The module is positioned for functional customization development, indicating that OEM-specific configurations can be discussed with YiYuan ComTech Co., Ltd.
All parameters below apply at VDC = 24–32 V, Tc = 50 °C, 50 W CW system conditions as published in the product datasheet.
| Parameter | Min | Typ | Max | Unit |
|---|---|---|---|---|
| Operating Frequency Range | 100 | — | 6000 | MHz |
| Operating Bandwidth | — | 150 | — | MHz |
| Peak Output Power (CW) | — | 50 | — | W |
| Power Gain (at 0 dBm input) | — | 47 ± 3 | — | dB |
| Gain Flatness (at 0 dBm input) | — | — | ±1 | dB |
| Efficiency | 50 | 52 | 55 | % |
| Harmonics 1 to N (at 50 W output) | 12 | 13 | 15 | dBc |
| Spurious Level | 60 | — | — | dBc |
| Output VSWR | — | — | 2:1 | — |
| Operating Voltage | 24 | 28 | 32 | V DC |
| Current Consumption (at 50 W output) | — | 3.5 | — | A |
A gain flatness of ±1 dB maximum across the 150 MHz instantaneous bandwidth is relevant for applications requiring consistent signal fidelity within an operating channel.
The module uses a Hybrid D-Sub 10-Pin Male connector for both DC power and all monitoring/control signals.
| Pin | Signal | Description |
|---|---|---|
| 1 | GND | Ground |
| 2 | TEMP | Analog voltage at 10 mV/°C (module temperature) |
| 3 | VSWR | Voltage standing wave alarm |
| 4 | PA_EN | Amplifier enable: TTL logic 3.3 V = ON, 0 V = OFF |
| 5 | +28 V | +28 V DC main supply |
| 6 | GND | Ground |
| 7 | CURR | Current sense: 100 mV per ampere |
| 8 | FWD | Forward power detection: 50 mV/1 dB |
| 9 | +5 V | External 5 V bias supply |
| 10 | +28 V | +28 V DC (second pin) |
The host system must be able to supply both the +28 V main rail and a separate +5 V bias rail through this connector.
The 100~6200MHz 50w Function with VSWR、Detection、TEMP has a rated operating range spanning 100 MHz to 6000 MHz, covering VHF, UHF, L-band, S-band, and C-band through the lower edge of the 5G sub-6 GHz range.
Fit check: If all system frequencies fall within 100–6000 MHz, the module's range is compatible. Applications requiring coverage above 6000 MHz—such as X-band radar—fall outside the rated operating range and this module is not an appropriate choice.
The module delivers 50 W typical CW output power. At the specified 52% typical efficiency, the DC input power draw is approximately 96 W at full output (3.5 A at 28 V nominal).
Fit check: Systems requiring up to 50 W at the antenna port are a direct match. Applications requiring substantially higher total radiated power would need multiple combined modules. Very low-power applications are overspecified for this module.
Pin 3 provides a VSWR alarm output (voltage standing wave alarm). The output VSWR is rated at 2:1 maximum.
Fit check: Field-deployed, vehicle-mounted, or mobile platform systems where antenna impedance mismatch is likely benefit directly from the built-in VSWR alarm. The host system must read and act on the Pin 3 signal to use this protection feature; if no VSWR signal conditioning is planned, the alarm is unused but the module remains operational.
Pin 2 (TEMP) outputs an analog voltage at 10 mV/°C, allowing a host controller to track module thermal state continuously.
Fit check: Systems operating in variable ambient temperatures, enclosed chassis, or high duty-cycle environments benefit from real-time thermal telemetry. The host system must include an ADC input to read this signal. If not, thermal margins must be managed through passive cooling design without closed-loop feedback.
Pin 8 (FWD) provides forward power detection at 50 mV/1 dB, enabling transmit power monitoring or closed-loop ALC without an external directional coupler.
Fit check: Integrations requiring transmit power verification or closed-loop output level control can use the onboard detector directly. If no power monitoring is required, Pin 8 can be left unconnected.
The PA_EN enable line (Pin 4) uses TTL logic: 3.3 V = ON, 0 V = OFF.
Fit check: Most modern microcontrollers and FPGAs with 3.3 V I/O can drive Pin 4 directly. Systems using 5 V TTL logic will need a level shifter on the enable line.
The 24–32 V DC wide-voltage input supports vehicle electrical systems, battery-backed field equipment, or regulated 28 V avionics-style power buses. A separate 5 V bias supply (Pin 9) is also required.
Fit check: Platforms with a 24 V or 28 V main bus are within the operating window. Supplies below 24 V or above 32 V are outside the rated input range.
The 100~6200MHz 50w Function with VSWR、Detection、TEMP is well-suited for:
This module is not the optimal choice when:
Before contacting YiYuan ComTech Co., Ltd., verify the following against your system design:
YiYuan ComTech Co., Ltd. specializes in RF power amplifiers, detectors, and related RF solutions for communication, security, and defense applications. The 100~6200MHz 50w Function with VSWR、Detection、TEMP module is listed under their Products category with a focus on functional customization development, reflecting an OEM and system-integration orientation. For application-specific questions or custom configuration inquiries, contact YiYuan ComTech Co., Ltd. through their official channel at www.drone-system.com.
THE COMPANY
Shenzhen Yiyuan is a leading technology company specializing in the research, development, and manufacturing of high-performance RF (radio frequency) solutions. With a strong focus on innovation and quality, we provide a comprehensive range of RF products, including RF power amplifiers, detectors, and jammers. Our advanced systems are designed to meet the demands of modern communication, security, and defense applications.…
About Us ↗Visit company website ↗YOUR NEXT STEP
Use case, specification, quantity and delivery window: make the next conversation specific.